Hepatic segmentation · CT

See the liver and every lesion in it, in minutes.

Upload an abdominal CT. Liver Lens outlines the liver and its tumours on every slice, measures their volumes, and builds a 3D model you can turn in the browser — with a report ready to print.

Research prototype. Not a medical device and not for diagnosis.

Liver Lesion Axial slice · illustration

How it works

  1. 1

    Upload a CT volume

    Drop a NIfTI file (.nii or .nii.gz) and attach it to a patient. Scans queue and run one at a time, so a busy morning never runs the server out of memory.

  2. 2

    Segment slice by slice

    A U-Net trained on the LiTS liver-tumour dataset windows each slice to soft tissue and labels liver and tumour. Small specks are removed and lesions are counted as connected regions.

  3. 3

    Review, measure, report

    Scroll the slices with the mask overlaid, turn the 3D reconstruction, read liver and lesion volumes in millilitres, and export a PDF report.

Built for a reading room, not a notebook

2D slice viewer

Axial, coronal and sagittal planes with the segmentation overlaid, real Hounsfield units under the cursor, and window presets.

3D reconstruction

Liver and lesion surfaces meshed from the mask, in true physical scale, rotatable in the browser, and downloadable as STL for 3D printing.

Volumes you can quote

Liver volume, lesion count and each lesion's size, computed from the scan's own voxel spacing rather than from pixels.

Printable report

A PDF with the key slices, the measurements and the model that produced them, ready for the case file.

Clinics kept apart

Several clinics share one installation; each sees only its own patients and scans, enforced on the server for every request.

Roles and invitations

Administrators, clinicians and read-only reviewers. New staff join by email invitation, and nobody shares a password.

The model

A 2D U-Net (four levels, 32 base channels) with two outputs — liver and tumour — trained on 128×128 slices windowed to −100…400 HU. The numbers are from its validation split during training, and they describe slices, not patients.

Validation figures are not clinical performance. Liver Lens has not been evaluated prospectively and must not be used to make decisions about patient care.

Dice · liver
0.835
Dice · tumour
0.915
Precision
0.946
Recall
0.842